COOLING TOWER
Cooling Tawor
Type of problems occurs in Cooling Towers
Mark
Corrosion
Mark
Scaling
Mark
Fouling
Mark
Microbiological growth
Corrosion (An Electrochemical Reaction)
Mark Pitting Corrosion
Mark Erosion Corrosion
Mark Stress Cracking Corrosion
Mark Galvanic Corrosion
   
 
Scaling
Mark CaCO3 : Due to breakdown of bicarbonate
Mark CaSO4 : Due to Calcium & Sulphate
Mark CaPO4 : Usually too much water treatment
Mark CaSiO2 : High concentration of Silica
Mark MnO2 : High level of Manganese & Oxide
Mark MgSiO2 : High level of Magnesium &  Silicates
Mark MgCO3 : High level of Magnesium with High pH & CO2
Mark Iron Oxide : Caused by lack of corrosion control or naturally occurring ion being oxidized
Mark Iron Phosphate : Compound caused by poor film formation of the phosphate inhibitor
 
Reasons For Corrosion:
Mark  
Metallurgy of the system
Mark
Dissolved gases
 
Mark  
pH of the circulation water
Mark Water  velocity  
Mark  
Suspended and dissolved solids
Mark Microbial growth  
 
Fouling (Deposition of suspended solids)
Mark
Biological Growth
: Due to Algae
Mark
Corrosion Products
: Due to Corrosion products
Mark Slit
: Due to insoluble Particles like Si, Al
Mark Others
: Air particles, Contamination like Oil, Process Leaks
 
Microbiological Growth
Mark
Algae
Mark
Fungi
Mark
Bacteria
Mark
Iron Bacteria
Mark Sulphate reducing Bacteria
 
Cooling Tower & Chilling Plant Water Treatment Chemicals
(Open Circuit & Closed Circuit)
 
 
Mark Scale and Corrosion Inhibitor for Low, Moderate and High Hardness of Water
Mark Oxidising Biocides, non Oxidizing Biocides for Algae Control
Mark Corrosion and Scale inhibitor for Closed Circuit Cooling Towers
Mark Bio dispersant
Mark pH Controller for Cooling Tower
Mark Corrosion Inhibitor for Calciam Chloride and Sodium Chloride Solution for Chilling Plant
Mark Corrosion Inhibitor for Chilled Water and Ethylene Glycol System for Chilling Plant
   
   
 
PRODUCT NO.
NAME OF THE PRODUCT
DESCRIPTION
Chemclin - 201 Non Oxidising Biocides It Control Algae formation in Cooling Tower.
Chemclin - 211 Non Oxidising Biocides It is Weekly dosing Biocide and alternat Chemclin-201.
Chemclin - 221 Scale and Corrosion Inhibitor It Control Scale & Corrosion in Cooling Tower. It is Specially Formulated Chemical Depend on High Hardness, Moderate Hardness & Low Hardness of Cooling Tower.
Chemclin - 231 Oxidising Biocide Oxidising Biocides which Controls the Algae formation in cooling Tower.
Chemclin - 241 Scale & Corrosion Inhibitor for Closed Cooling system It is Specially Designed Compound to prevent Scaling & Corrosion in Closed Circuit Cooling System.
Chemclin - 261 pH Contoller for Cooling Tower It Controls the pH of Cooling Tower & Prevent high pH Corrosion in Cooling Tower.
Also we can Manufacture Specific Products as party's requirements